Error code format
The error codes follows the format: ARSSCEEE, where:
- A (Fixed)
- A = unknown
- R (Reserved)
- 0-E = Unknown
- F = Frequent error
- SS (Step)
- 00-7F = Step of the power on sequence where the error happened
- 80 = The error happened when the PS3 was powered on
- 90 = The error happened when the PS3 was powered off
- A0 = The error happened after a syscon reset
- C (Category)
- 1 = System
- 2 = Fatal
- 3 = Boot
- 4 = Data
- EEE (Error)
- Any number in hex
The list below only includes the last 4 numbers (category + error)
Error codes
1001
Cell Vram Power
1002
RSX Vram Power
1004
PSU Power
|