Thermal: Difference between revisions
Jump to navigation
Jump to search
mNo edit summary |
mNo edit summary |
||
Line 20: | Line 20: | ||
* [http://mods.elotrolado.net/~hermes/ps3/control_fan_utility_v1.0.rar control_fan_utility_v1.0.rar] (including source) [http://www.mirrorcreator.com/files/1OFDEDNC/control_fan_utility_v1.0.rar_links mirror] for 3.41, 3.55, 4.21, 4.30 and 4.40 // [http://www.elotrolado.net/hilo_utilidad-control-fan-utility-v1-0-cfw-cex-3-41-3-55-4-21-4-30-4-31-y-4-40_1893851 original thread] | * [http://mods.elotrolado.net/~hermes/ps3/control_fan_utility_v1.0.rar control_fan_utility_v1.0.rar] (including source) [http://www.mirrorcreator.com/files/1OFDEDNC/control_fan_utility_v1.0.rar_links mirror] for 3.41, 3.55, 4.21, 4.30 and 4.40 // [http://www.elotrolado.net/hilo_utilidad-control-fan-utility-v1-0-cfw-cex-3-41-3-55-4-21-4-30-4-31-y-4-40_1893851 original thread] | ||
* [http://mods.elotrolado.net/%7Ehermes/ps3/control_fan_utility_v1.6.rar control_fan_utility_v1.6.rar] (added support for Remote Play) [http://rapidshare.com/files/3792710738/control_fan_v1.6%28remoteplay%29.pkg mirror] // [http://www.elotrolado.net/hilo_utilidad-control-fan-utility-v1-6-cfw-cex-3-41-3-55-4-21-4-30-4-31-y-4-40_1893851 original thread] | * [http://mods.elotrolado.net/%7Ehermes/ps3/control_fan_utility_v1.6.rar control_fan_utility_v1.6.rar] (added support for Remote Play) [http://rapidshare.com/files/3792710738/control_fan_v1.6%28remoteplay%29.pkg mirror] // [http://www.elotrolado.net/hilo_utilidad-control-fan-utility-v1-6-cfw-cex-3-41-3-55-4-21-4-30-4-31-y-4-40_1893851 original thread] | ||
* [http://mods.elotrolado.net/%7Ehermes/ps3/irismanager-4-x.rar irismanager-4-x.rar] (with fancontrol/thermal output) // [http://www.elotrolado.net/hilo_aplicacion-iris-manager-v2-40_1862716 original thread] | |||
Revision as of 10:12, 11 May 2013
CELL BE internal Powermanagement
Characteristics
- Dynamic Power Managment with 5 power managment states
- 1 linear sensor
- 10 digital thermal sensors (8xSPE, PPE and?)
- THERM signal(s) are sent to Syscon Hardware via SMbus
Readout of Thermal data using Software
Readable in software : LV2 sc383 sys_game_get_temperature / sc384 sys_sm_get_tzpb
Homebrew for thermal (and fan) data / control
- control_fan_utility_v0.3.rar (including source) mirror for 4.31 and 4.40 // original thread
- control_fan_utility_v1.0.rar (including source) mirror for 3.41, 3.55, 4.21, 4.30 and 4.40 // original thread
- control_fan_utility_v1.6.rar (added support for Remote Play) mirror // original thread
- irismanager-4-x.rar (with fancontrol/thermal output) // original thread
Speculation
- Attackvector for clock-slowdown?
AD51/067ARMZ-REEL (2 channel Thermal Monitor SMbus IC)
6-710-287-01 / IC1101
Used for monitoring the CELL BE
Pin | Signal | Description |
---|---|---|
1 | VCC | +3.3_Thermal |
2 | D+ | from STI_THERMAL0 via R1106 100 Ohm and C1103 0.001uF 50V |
3 | D- | from STI_THERMAL0 via R1107 100 Ohm and C1103 0.001uF 50V |
4 | /THERM | |
5 | GND | Ground |
6 | /THERM2 | to /SYS_THR_ALRT |
7 | SDATA | from THR_I2C_SDA |
8 | SCLK | from THR_I2C_SCL |
OnSemi ADT7461A0002RMZR (2 channel Thermal Monitor SMbus IC CELL BE/RSX)
6-710-286-01 / IC2101
Used for monitoring the RSX
Datasheet: ADT7461-D.PDF
Pin | Signal | Description |
---|---|---|
1 | VCC | +3.3_Thermal |
2 | D+ | from RSX_TDR via R2101 100 Ohm and C2103 0.001uF 50V |
3 | D- | from RSX_TDN via R2102 100 Ohm and C2103 0.001uF 50V |
4 | /THERM | to RSX_GPIO6 / RSX_THR_EVENT |
5 | GND | Ground |
6 | /THERM2 | to /THRRSX_SENS_ALRT |
7 | SDATA | from THR_I2C_SDA |
8 | SCLK | from THR_I2C_SCL |