Wiring
Jump to navigation
Jump to search
Wire reference[edit | edit source]
For wiring, use 20-28 AWG. 18 can be too stiff while 30 is too fragile. 24-26 AWG works fine in most cases. The Grounds and VCC wires may ofcourse be thicker than the signal wires. Keep wires short, up to ~20cm max (longer gives errors). The shorter the better : 15cm and shorter mostly works fine with AWG26 on SPI.
Use caliper to measure unknown/unmarked wires and compare with table/listing.
Table: AWG (inch) / Euro (mm)[edit | edit source]
American Wire Gauge |
Diameter | Cross Sectional Area |
Diameter | Cross Sectional Area |
Notes |
---|---|---|---|---|---|
(AWG) | d (inch) | A (inch2) | d (mm) | A (mm2) | |
0000 (-3) | 0,4600 | 0,1662 | 11,6839 | 107,2172 | |
000 (-2) | 0,4096 | 0,1318 | 10,4048 | 85,0279 | |
00 (-1) | 0,3648 | 0,1045 | 9,2658 | 67,4308 | |
0 | 0,3249 | 0,0829 | 8,2515 | 53,4756 | |
1 | 0,2893 | 0,0657 | 7,3482 | 42,4085 | |
2 | 0,2576 | 0,0521 | 6,5438 | 33,6318 | |
3 | 0,2294 | 0,0413 | 5,8275 | 26,6715 | |
4 | 0,2043 | 0,0328 | 5,1895 | 21,1516 | |
5 | 0,1819 | 0,0260 | 4,6214 | 16,7742 | |
6 | 0,1620 | 0,0206 | 4,1155 | 13,3027 | |
7 | 0,1443 | 0,0164 | 3,6650 | 10,5496 | |
8 | 0,1285 | 0,0130 | 3,2638 | 8,3663 | |
9 | 0,1144 | 0,0103 | 2,9065 | 6,6348 | |
10 | 0,1019 | 0,0082 | 2,5883 | 5,2617 | |
11 | 0,0907 | 0,0065 | 2,3050 | 4,1728 | |
12 | 0,0808 | 0,0051 | 2,0527 | 3,3092 | |
13 | 0,0720 | 0,0041 | 1,8279 | 2,6243 | |
14 | 0,0641 | 0,0032 | 1,6278 | 2,0812 | |
15 | 0,0571 | 0,0026 | 1,4496 | 1,6505 | |
16 | 0,0508 | 0,0020 | 1,2910 | 1,3089 | |
17 | 0,0453 | 0,0016 | 1,1496 | 1,0380 | |
18 | 0,0403 | 0,0013 | 1,0238 | 0,8232 | |
19 | 0,0359 | 0,0010 | 0,9117 | 0,6528 | |
20 | 0,0320 | 0,0008 | 0,8119 | 0,5177 | |
21 | 0,0285 | 0,0006 | 0,7230 | 0,4106 | |
22 | 0,0253 | 0,0005 | 0,6439 | 0,3256 | |
23 | 0,0226 | 0,0004 | 0,5734 | 0,2582 | |
24 | 0,0201 | 0,0003 | 0,5106 | 0,2048 | |
25 | 0,0179 | 0,0003 | 0,4547 | 0,1624 | |
26 | 0,0159 | 0,0002 | 0,4049 | 0,1288 | |
27 | 0,0142 | 0,0002 | 0,3606 | 0,1021 | |
28 | 0,0126 | 0,0001 | 0,3211 | 0,0810 | |
29 | 0.0113 | 0.286 | 0.064 | ||
30 | 0.0100 | 0.255 | 0.051 | ||
31 | 0.00893 | 0.227 | 0.040 | ||
32 | 0.00795 | 0.202 | 0.032 | ||
33 | 0.00708 | 0.180 | 0.025 | ||
34 | 0.00631 | 0.160 | 0.020 | ||
35 | 0.00562 | 0.143 | 0.016 | ||
36 | 0.00500 | 0.127 | 0.013 | ||
37 | 0.00445 | 0.113 | 0.010 | ||
38 | 0.00397 | 0.101 | 0.008 | ||
39 | 0.00353 | 0.0897 | 0.006 | ||
40 | 0.00314 | 0.0799 | 0.005 |
Alternative/cable comparison[edit | edit source]
PATA/floppy 40-conductor cable - AWG28 (0.0126" / 0.321mm) with 0.0333" pitch +/- 0.002" PATA/floppy 40-conductor cable - AWG30 (0.0100" / 0.255mm) with 0.0333" pitch +/- 0.002" PATA 80-conductor cable - AWG30 (0.0100" / 0.255mm) with 0.025" pitch +/- 0.0016" PATA 80-conductor cable - AWG30 (0.0100" / 0.255mm) with 0.025" pitch +/- 0.002" PATA 80-conductor cable - AWG31 (0.00893" / 0.227mm) with 0.025" pitch +/- 0.002" PATA 80-conductor cable - AWG32 (0.00795" / 0.202mm) with 0.025" pitch +/- 0.002" Category 6 (ANSI/TIA-568-B.2-1) network cable: 4 twisted pairs of 22AWG (0.0253" / 0.644mm) Category 6 (ANSI/TIA-568-B.2-1) network cable: 4 twisted pairs of 23AWG (0.0226" / 0.573mm) Category 6 (ANSI/TIA-568-B.2-1) network cable: 4 twisted pairs of 24AWG (0.0201" / 0.511mm) Category 5/5e (TIA/EIA 568-5-A) network cable: 4 twisted pairs of 24AWG (0.0201" / 0.511mm) Category 5e patch (TIA/EIA 568-5-A) network cable: 4 twisted pairs of 26AWG (0.0159" / 0.405mm) SATA : solid 26 AWG - 0.0159" / 0.405mm SATA : solid 28 AWG - 0.0126" / 0.321mm SATA : solid 30 AWG - 0.0100" / 0.255mm
External Reference[edit | edit source]
|