Syscon Error Codes: Difference between revisions
Jump to navigation
Jump to search
m (→System) |
m (→Fatal) |
||
Line 78: | Line 78: | ||
=== Fatal === | === Fatal === | ||
==== | ==== 2001 ==== | ||
Cell | |||
==== | ==== 2002 ==== | ||
RSX | |||
==== | ==== 2003 ==== | ||
Southbridge | |||
==== | ==== 2010 ==== | ||
Clock 1 | |||
==== | ==== 2011 ==== | ||
Clock 3 | |||
==== | ==== 2012 ==== | ||
Clock 2 | |||
==== | ==== 2013 ==== | ||
Clock 4 | |||
==== | ==== 2020 ==== | ||
HDMI | |||
==== | ==== 2022 ==== | ||
DVE | |||
==== | ==== 2030 ==== | ||
Thermal sensor 1 | |||
==== | ==== 2031 ==== | ||
Thermal sensor 2 | |||
==== | ==== 2033 ==== | ||
Thermal sensor 3 | |||
==== | ==== 2101 ==== | ||
Cell | |||
==== | ==== 2102 ==== | ||
RSX | |||
==== | ==== 2103 ==== | ||
Southbridge | |||
==== | ==== 2110 ==== | ||
Clock 1 | |||
==== | ==== 2111 ==== | ||
Clock 3 | |||
==== | ==== 2112 ==== | ||
Clock 2 | |||
==== | ==== 2113 ==== | ||
Clock 4 | |||
==== | ==== 2120 ==== | ||
HDMI | |||
==== | ==== 2122 ==== | ||
DVE | |||
==== | ==== 2130 ==== | ||
Thermal sensor 1 | |||
==== | ==== 2131 ==== | ||
Thermal sensor 2 | |||
==== | ==== 2133 ==== | ||
Thermal sensor 3 | |||
==== | ==== 2203 ==== | ||
Southbridge | |||
=== Boot === | === Boot === |
Revision as of 11:15, 6 November 2021
Error code format
The error codes follows the format: ARSSCEEE, where:
- A (Fixed)
- A = unknown
- R (Reserved)
- 0-E = Unknown
- F = Frequent error
- SS (Step)
- 00-7F = Step of the power on sequence where the error happened
- 80 = The error happened when the PS3 was powered on
- 90 = The error happened when the PS3 was powered off
- A0 = The error happened after a syscon reset
- C (Category)
- 1 = System
- 2 = Fatal
- 3 = Boot
- 4 = Data
- EEE (Error)
- Any number in hex
The list below only includes the last 4 numbers (category + error)
Error codes
System
1001
Cell Vram Power
1002
RSX Vram Power
1004
PSU Power
1103
Thermal
1200
Cell thermal
1201
RSX thermal
1203
Cell voltage regulators thermal
1204
Southbridge thermal
1205
EE/GS thermal
1301
Cell PLL
14FF
Check stop
1601
Cell livelock
1701
Cell attention
1802
RSX init
1900
RTC voltage
1901
RTC oscilator
1902
RTC access
Fatal
2001
Cell
2002
RSX
2003
Southbridge
2010
Clock 1
2011
Clock 3
2012
Clock 2
2013
Clock 4
2020
HDMI
2022
DVE
2030
Thermal sensor 1
2031
Thermal sensor 2
2033
Thermal sensor 3
2101
Cell
2102
RSX
2103
Southbridge
2110
Clock 1
2111
Clock 3
2112
Clock 2
2113
Clock 4
2120
HDMI
2122
DVE
2130
Thermal sensor 1
2131
Thermal sensor 2
2133
Thermal sensor 3
2203
Southbridge
Boot
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
Data
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
|