Introduction
- No use actually but just for the sake of scientific research :)
Current BD FW Version
Using Storage Manager service get_version:
sudo ./ps3dm sm get_version 00 03 00 50 00 00 00 00
Using SC Manager service get_region_data:
sudo ps3dm scm get_region_data 8 | hexdump -C 00000000 00 03 00 50 00 00 00 00 00 00 00 00 00 00 00 00 |...P............| 00000010 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 |................| * 00000030
Or reading it from BD drive istelf, see: Get Version
BD Drive Type
- Use SCSI Inquiry to fetch BD drive identification string.
sudo sg_inq /dev/sr0
- PUP file contains several BD update packages.
- Update manager matches BD drive type against h_id from update package header.
- h_id is at offset 0x8 (8 bytes) in the update package header.
- E.g. h_id from BDPT_FIRMWARE_PACKAGE_306R.pkg is 0x0000000000000007.
Identification string | Type | Flag |
---|---|---|
SONY EmerFlashROM | 0x2100000000000001 | 0 |
SONY PS-EMBOOT 300R | 0x2100000000000001 | 0 |
SONY BDRW AQUAM(BDIT) | 0x1100000000000001 | 0 |
SONY PS-SYSTEM 300R | 0x1100000000000001 | 0 |
SONY PS-SYSTEM V300 | 0x1100000000000001 | 0 |
SCEI EMER-FLASH-8 | 0x2200000000000002 | 0 |
SONY PS-EMBOOT 301R | 0x2200000000000002 | 0 |
SONY PS-SYSTEM 301R | 0x1200000000000002 | 0 |
SONY PS-EMBOOT 302R | 0x2200000000000003 | 1 |
SONY PS-SYSTEM 302R | 0x1200000000000003 | 1 |
SONY PS-EMBOOT 303R | 0x2200000000000004 | 0 |
SONY PS-SYSTEM 303R | 0x1200000000000004 | 0 |
SONY PS-EMBOOT 304R | 0x2200000000000005 | 1 |
SONY PS-SYSTEM 304R | 0x1200000000000005 | 1 |
SONY PS-EMBOOT 306R | 0x2200000000000007 | 1 |
SONY PS-SYSTEM 306R | 0x1200000000000007 | 1 |
SONY PS-EMBOOT 308R | 0x2200000000000008 | 1 |
SONY PS-SYSTEM 308R | 0x1200000000000008 | 1 |
SONY PS-EMBOOT 310R | 0x2200000000000009 | 1 |
SONY PS-SYSTEM 310R | 0x1200000000000009 | 1 |
SONY PS-EMBOOT 312R | 0x220000000000000A | 1 |
SONY PS-SYSTEM 312R | 0x120000000000000A | 1 |
SONY PS-EMBOOT 314R | 0x220000000000000B | 1 |
SONY PS-SYSTEM 314R | 0x120000000000000B | 1 |
SONY PS-EMBOOT 316R | 0x220000000000000C | 1 |
SONY PS-SYSTEM 316R | 0x120000000000000C | 1 |
SONY PS-EMBOOT 318R | 0x220000000000000D | 1 |
SONY PS-SYSTEM 318R | 0x120000000000000D | 1 |
BD drive type and FW type check:
if ((type & 0x00FFFFFFFFFFFFFF) == h_id) FW is OK else FW is NOT OK fi
Sending BD Firmware to BD Drive
- BD update package is first decrypted and then sent to BD drive.
- BD buffer 0 is used to send BD firmware to BD drive.
- The BD firmware is sent in chunks of size 0x8000 bytes with SCSI command WRITE BUFFER mode 7.
See my bd_update_fw tool for PS3 Linux.
http://gitorious.ps3dev.net/ps3linux/bd-tools
Test
- Tested with my PS3 slim and OtherOS++.
- It should work on PC too. You can update your BD drive on PC but first you need to authenticate it with bd_get_version.
- Downgrading works too. I tested it myself and downgraded from 3.50 to 3.40 and back again.
- Use ps3dm sm get_version or bd_get_version to verify that the new version was installed successfully.
Valid firmware:
sudo ./bd_update_fw -v -f ~/ofw355/BDPT_FIRMWARE_PACKAGE_306R.bin/content firmware length 786432 firmware h_id 0 === INQUIRY (0x12) === vendor id SONY product id PS-SYSTEM 306R === START STOP (0x1b) === === TEST UNIT READY (0x00) === === WRITE BUFFER (0x3b): offset 0 length 8000 === === WRITE BUFFER (0x3b): offset 8000 length 8000 === === WRITE BUFFER (0x3b): offset 10000 length 8000 === === WRITE BUFFER (0x3b): offset 18000 length 8000 === === WRITE BUFFER (0x3b): offset 20000 length 8000 === === WRITE BUFFER (0x3b): offset 28000 length 8000 === === WRITE BUFFER (0x3b): offset 30000 length 8000 === === WRITE BUFFER (0x3b): offset 38000 length 8000 === === WRITE BUFFER (0x3b): offset 40000 length 8000 === === WRITE BUFFER (0x3b): offset 48000 length 8000 === === WRITE BUFFER (0x3b): offset 50000 length 8000 === === WRITE BUFFER (0x3b): offset 58000 length 8000 === === WRITE BUFFER (0x3b): offset 60000 length 8000 === === WRITE BUFFER (0x3b): offset 68000 length 8000 === === WRITE BUFFER (0x3b): offset 70000 length 8000 === === WRITE BUFFER (0x3b): offset 78000 length 8000 === === WRITE BUFFER (0x3b): offset 80000 length 8000 === === WRITE BUFFER (0x3b): offset 88000 length 8000 === === WRITE BUFFER (0x3b): offset 90000 length 8000 === === WRITE BUFFER (0x3b): offset 98000 length 8000 === === WRITE BUFFER (0x3b): offset a0000 length 8000 === === WRITE BUFFER (0x3b): offset a8000 length 8000 === === WRITE BUFFER (0x3b): offset b0000 length 8000 === === WRITE BUFFER (0x3b): offset b8000 length 8000 === === TEST UNIT READY (0x00) === req sense 20407 (because of invalid command issued. ignore it) === TEST UNIT READY (0x00) === req sense 20407 (because of invalid command issued. ignore it) === TEST UNIT READY (0x00) === req sense 20407 (because of invalid command issued. ignore it) === TEST UNIT READY (0x00) === req sense 20407 (because of invalid command issued. ignore it) === TEST UNIT READY (0x00) === req sense 20407 (because of invalid command issued. ignore it) === TEST UNIT READY (0x00) === req sense 20407 (because of invalid command issued. ignore it) === TEST UNIT READY (0x00) === req sense 20407 (because of invalid command issued. ignore it) === TEST UNIT READY (0x00) === req sense 20407 (because of invalid command issued. ignore it) === TEST UNIT READY (0x00) === req sense 20401 (unknown) === TEST UNIT READY (0x00) === req sense 20401 (unknown) === TEST UNIT READY (0x00) === req sense 20401 (unknown) === TEST UNIT READY (0x00) === req sense 20401 (unknown) === TEST UNIT READY (0x00) === req sense 20401 (unknown) === TEST UNIT READY (0x00) === req sense 20401 (unknown) === TEST UNIT READY (0x00) === req sense 23a00 (success)
Invalid firmware:
sudo ./bd_update_fw -v -f ~/ofw355/BDPT_FIRMWARE_PACKAGE_306R.bin/info1 firmware length 64 firmware h_id 0 === INQUIRY (0x12) === vendor id SONY product id PS-SYSTEM 306R === START STOP (0x1b) === === TEST UNIT READY (0x00) === === WRITE BUFFER (0x3b): offset 0 length 40 === WRITE BUFFER failed: req sense 52600 (invalid firmware combination or hash error)