Editing Talk:Cex2Dex
Jump to navigation
Jump to search
The edit can be undone. Please check the comparison below to verify that this is what you want to do, and then publish the changes below to finish undoing the edit.
Latest revision | Your text | ||
Line 1: | Line 1: | ||
= External references = | = External references = | ||
* [ | * [http://www.ps3hax.net/showthread.php?p=400529#post400529] | ||
= CEX2DEX - pro versus con = | = CEX2DEX - pro versus con = | ||
Line 18: | Line 18: | ||
|- | |- | ||
| Downgrading || {{Yes}} || {{Yes}} || {{Yes}} || Restricted to minver of that SKU/type (either metldr minver locked, or because of drivers - same limitations as Retail/CEX, but without hardware flasher) | | Downgrading || {{Yes}} || {{Yes}} || {{Yes}} || Restricted to minver of that SKU/type (either metldr minver locked, or because of drivers - same limitations as Retail/CEX, but without hardware flasher) | ||
|- | |||
|} | |} | ||
Line 57: | Line 58: | ||
<small>Note:<br /> | <small>Note:<br /> | ||
Can use [[QA Flagging#Debug Menu settings not in Retail/CEX QA|QA debug]] (<=3.56) or setmonitor.self (ProDG Target Manager - Monitor Settings Utility). See also [[XRegistry.sys#Common Settings|"XRegistry.sys /setting/display/0/hdcp"]] to enforce it to "off" setting.</small> | Can use [[QA Flagging#Debug Menu settings not in Retail/CEX QA|QA debug]] (<=3.56) or setmonitor.self (ProDG Target Manager - Monitor Settings Utility). See also [[XRegistry.sys#Common Settings|"XRegistry.sys /setting/display/0/hdcp"]] to enforce it to "off" setting.</small> | ||
|- | |- | ||
| Burned Master Discs || {{No}} || {{No}} || {{No}} || Hardware limitations in the Drive Id's (OTP not set to 0xFFFFFFFFFFFFFFFF) prevent from using burned ps3 and ps2 masterdiscs (they are recognized as data discs), this is a check performed by the drive's firmware. | | Burned Master Discs || {{No}} || {{No}} || {{No}} || Hardware limitations in the Drive Id's (OTP not set to 0xFFFFFFFFFFFFFFFF) prevent from using burned ps3 and ps2 masterdiscs (they are recognized as data discs), this is a check performed by the drive's firmware. | ||
|- | |||
|} | |} | ||
Note about 3.56 : would need to use custom generated keys for signing, as the random fail is fixed since that version, thus no private keys can be acquired with Scekrit). | |||
Note about | |||
= Alternative method of writing back flash (jaicrab / bad idea) = | = Alternative method of writing back flash (jaicrab / bad idea) = | ||
Put these, including your target NOR file, named rflash.bin on a stick | Put these, including your target NOR file, named rflash.bin on a stick | ||
https://dl.dropbox.com/u/35197530/Lv2diag.self | |||
https://dl.dropbox.com/u/35197530/advance.cfg | |||
Either use PSgrade/JIG and let the lv2diag.self be executed by lv1.self automaticly, or use MultiMAN self loader<br /> | |||
Will take a LONG time (35 minutes) until console stops blinking and shutdown with red led. | |||
Tested working on CECHG fat (256MB NAND). II suspect the reason for people bricking was they were flashing dumps of different lenghts and offsets (such as from memdump) and not the one provided by dumping with this. -sk1080 | |||
---- | |||
= CEX2DEX NOR Guide = | = CEX2DEX NOR Guide = | ||
Line 164: | Line 168: | ||
|} | |} | ||
(above patches in a single package + autopatcher file: [http://www.mirrorcreator.com/files/1PQMPNIH/3.55_DEX_checkoff.rar_links 3.55_DEX_checkoff.rar]) |