Line 201: | Line 201: | ||
---- | ---- | ||
==== 1001 (Power | ==== 1001 (Power CELL) - Improper Shutdown Error ==== | ||
*Components Involved: | *Components Involved: | ||
**[[CELL BE|CELL]] (IC1001 on [[COK-001]]) | **[[CELL BE|CELL]] (IC1001 on [[COK-001]]) | ||
Line 215: | Line 215: | ||
Anecdote: One console, with faulty CPU NEC/TOKINs, displayed an A0901001 error only during shutdown. The Last of Us, a strenuous game, showed no signs of typical bad NEC/TOKIN behavior, and the system remained stable. However, it remained in shutdown for a prolonged period, resulting in the YLOD (3 beeps and flashing red light). It required a reset to power back on. Replacing the NEC/TOKINs resolved the problem. | Anecdote: One console, with faulty CPU NEC/TOKINs, displayed an A0901001 error only during shutdown. The Last of Us, a strenuous game, showed no signs of typical bad NEC/TOKIN behavior, and the system remained stable. However, it remained in shutdown for a prolonged period, resulting in the YLOD (3 beeps and flashing red light). It required a reset to power back on. Replacing the NEC/TOKINs resolved the problem. | ||
==== 1002 (Power RSX) ==== | ==== 1002 (Power RSX) - Overheating Error ==== | ||
*Components Involved: | *Components Involved: | ||
**[[RSX]] (IC2001 on [[COK-001]]) | **[[RSX]] (IC2001 on [[COK-001]]) | ||
Line 674: | Line 674: | ||
This error has been triggered when pad N12 (RSXVRM_VID0) was damaged, preventing RSX VDDC voltage from being set correctly. SYSCON sets the CPU VID just before the Config ring data is loaded. Apparently, SYSCON sets RSX VID on IC6201 (Buck Controller) at step number 32, which is just after. These voltages must be stable before the FlexIO can calibrated (BitTraining at Step No. 40 & ByteTraining at 50 & 51). | This error has been triggered when pad N12 (RSXVRM_VID0) was damaged, preventing RSX VDDC voltage from being set correctly. SYSCON sets the CPU VID just before the Config ring data is loaded. Apparently, SYSCON sets RSX VID on IC6201 (Buck Controller) at step number 32, which is just after. These voltages must be stable before the FlexIO can calibrated (BitTraining at Step No. 40 & ByteTraining at 50 & 51). | ||
====3034 ==== | ====3034 - BGA Error ==== | ||
[[CELL BE|CELL]] / [[RSX]] / [[South Bridge]] error during Bit-Training | [[CELL BE|CELL]] / [[RSX]] / [[South Bridge]] error during Bit-Training | ||