Line 491: | Line 491: | ||
This error has been resolved by a number of users who had a short on F6001. It is important to note that something usually causes that fuse to blow, like a short. So it's important to troubleshoot the board to find and repair the shorting component before replacing the fuse. Otherwise the new one will blow too. | This error has been resolved by a number of users who had a short on F6001. It is important to note that something usually causes that fuse to blow, like a short. So it's important to troubleshoot the board to find and repair the shorting component before replacing the fuse. Otherwise the new one will blow too. | ||
One user, who resolved this error on his C model PS3, noted "very short YLOD. Error code shows 2110[...]Some earlier code shows 1001 and 1002." The 1001 & 1002 errors he noted in the log before the 2110 appeared may have been a clue that C6019 | One user, who resolved this error on his C model PS3, noted "very short YLOD. Error code shows 2110[...]Some earlier code shows 1001 and 1002." The 1001 & 1002 errors he noted in the log before the 2110 appeared may have been a clue that C6019 was deteriorating. Further investigation is needed to confirm this hypothesis, however. In his case, C6019 was shorting and caused F6001 to blow. This short overloaded F6001 and cut power to many Subsystems, such as the HDD, USB ports, South bridge, CPU, GPU, etc. Β | ||
One particularly noteworthy component is IC6020, which supplys +3.3v_MK_Vdd to the clock generator (IC5001). When F6001 blows, a 02 2110 is generated. A step number of 02 is very early in the power on sequence (POS), which explains why 2110 is triggered instead of another error code. Since the clock generator is critical for timing, it is one of the first things the SYSCON checks during the POS. | One particularly noteworthy component is IC6020, which supplys +3.3v_MK_Vdd to the clock generator (IC5001). When F6001 blows, a 02 2110 is generated. A step number of 02 is very early in the power on sequence (POS), which explains why 2110 is triggered instead of another error code. Since the clock generator is critical for timing, it is one of the first things the SYSCON checks during the POS. |