Another user confirmed this. The error log was showing code 2110 and one entry earlier was showing code 1001. Checking both capacitors after removing them from the board, confirmed that one capacitor was reading 140 ohms and not reading as a capacitor, so it was working as a resistor causing extra load in the fuse. | Another user confirmed this. The error log was showing code 2110 and one entry earlier was showing code 1001. Checking both capacitors after removing them from the board, confirmed that one capacitor was reading 140 ohms and not reading as a capacitor, so it was working as a resistor causing extra load in the fuse. | ||
One particularly noteworthy component is IC6020, which supplys +3.3v_MK_Vdd to the clock generator (IC5001). When F6001 blows, a 02 2110 is generated. A step number of 02 is very early in the | One particularly noteworthy component is IC6020, which supplys +3.3v_MK_Vdd to the clock generator (IC5001). When F6001 blows, a 02 2110 is generated. A step number of 02 is very early in the POS, which explains why 2110 is triggered instead of another error code. Since the clock generator is critical for timing, it is one of the first things the SYSCON checks during the power on sequence (POS). | ||
==== 2111 (Clock CELL) ==== | ==== 2111 (Clock CELL) ==== |